The useful buying question is how much electricity a machine needs to do your job. The lowest hourly cost does not necessarily give you the lowest cost to dry a washing load or manage a cold room.
Calculate your own running cost
Our calculator uses four inputs: power in watts, hours per day, number of days and your electricity unit rate in pence per kWh. Take the rate from your tariff, including VAT where applicable. The examples below use 26.32p/kWh, Ofgem’s published average electricity unit rate for Direct Debit customers in Great Britain for 1 October–31 December 2026, checked on 16 November. This is a useful default, not everyone’s tariff: rates vary by region and payment method. Use your bill for a fixed, time-of-use or Northern Ireland tariff. Ofgem’s unit rates.
The cap changes by calendar quarter, not on a rolling 90-day timer. The calculator dates the default and asks for your own rate if no verified rate covers the current period. It does not add VAT to Ofgem’s published consumer rate.
| Power used throughout the stated time | One hour | Eight hours | 30 days at eight hours a day |
|---|---|---|---|
| 100 W | 2.63p | 21.06p | £6.32 |
| 200 W | 5.26p | 42.11p | £12.63 |
| 300 W | 7.90p | 63.17p | £18.95 |
| 600 W | 15.79p | £1.26 | £37.90 |
These are power scenarios, not four equally capable appliances. They do not tell us how much water each machine removes, or how long it will take to finish.
The calculation is:
Cost in pounds = watts ÷ 1,000 × hours × electricity price in pence ÷ 100.
For a daily schedule, multiply by the number of days. The calculator excludes the electricity standing charge because it calculates the additional energy used by this appliance, not the whole household bill.
Switched on is not the same as drawing full power
An eight-hour timer tells you how long the machine is available to operate. It does not establish eight hours at one fixed wattage. A humidity-controlled appliance can change its behaviour as the room dries; different fan settings, defrosting and standby operation can also change consumption.
We therefore do not quietly assume that every dehumidifier runs its compressor half the time. There is no universal duty cycle that makes that a sound estimate. If all you have is a published operating wattage, the calculator gives a clearly labelled constant-power scenario.
If you already own a unit, a suitable plug-in energy meter can give you a more useful answer. Record total kWh over several representative days, alongside the operating hours, setting, room temperature and whether you dried washing. Divide the energy used by the days measured, then multiply by your tariff. Repeat when the task or season changes; a laundry day is not interchangeable with a day spent maintaining an already dry room.
A real specification example: Meaco Arete Two 20L
Meaco publishes 207 W and 8.50 litres per day at 20°C and 60% relative humidity for the Arete Two 20L. At the dated 26.32p/kWh default, 207 W is 5.45p an hour, or £13.08 over 30 eight-hour days if it draws that power continuously during those hours.
The same manufacturer's table gives 176 W and 3.35 litres per day at 10°C and 60% RH. Lower power in the colder test does not make it the better drying result: water collection also falls. These are manufacturer figures under stated conditions, not our measurements or a promise of what your house will collect. Meaco's extraction and power table.
Compare the job, not just the wattage
For a heated living space, start with models that suit your moisture load, then compare published extraction and power at matching temperature and humidity. If one brand only supplies a warm, very humid headline rating, that is a gap in the comparison, not a licence to pretend it matches a cooler test.
For a consistently cool room, technology matters. EcoAir describes around 15°C as a useful comparison point for considering desiccant machines, while explicitly warning that it is not a fixed cut-off. Check the individual operating range and cold-condition performance. A higher-powered machine can still be the more suitable choice if it does the job that the lower-powered option struggles with. EcoAir's technology guide.
For laundry, compare energy per completed load only when the test describes a comparable load, starting moisture, room and finish point. “Six hours to dry” beside “200 W” from an unrelated mode is not measured energy consumption. Our drying-clothes guide explains what matters before buying.
Is paying more for efficiency worthwhile?
Suppose two suitable machines differ by 50 W while doing the same job for the same eight hours a day. At 26.32p/kWh, that difference is about 10.53p a day. A £50 purchase premium would take about 475 such days to recover through electricity alone.
That is a break-even illustration, not a product verdict. If the machines dry at different speeds, or run for different proportions of the day, the result changes. Choose for the task first, then weigh energy costs alongside purchase price, noise, maintenance and warranty. Start with which dehumidifier do I need? or compare desiccant and compressor models.
Common questions
Does a 20-litre dehumidifier always cost more than a 12-litre one?
No conclusion follows from the names alone. Check power at comparable conditions and how long each needs to do the same job. Headline litres per day are not electricity consumption.
Can I just multiply the hourly cost by 24?
Yes, as a scenario in which that power is drawn for all 24 hours. It is not automatically the bill for a humidity-controlled machine left switched on all day.
Should I replace a working machine to save electricity?
Measure its consumption first. Compare the likely saving with the replacement cost, using the same task and operating conditions. A small hourly difference can take years of seasonal use to repay a new purchase.